One hundred laminar flow hood, clean laminar flow hood, 100 laminar flow operating room
Clean laminar flow (downflow) is a vertical one-way flow, to provide local class A environment, clean and sterile purification equipment; it is widely used in the pharmaceutical industry, in the clean environment C Create Class A, or create Class A in Class B clean environment. Has been very widely used in the pharmaceutical factory clean room cleanliness requires a higher local area. Such as dry and hot heat sterilization cabinet outlet laminar flow protection, freeze-drying machine export laminar flow protection, sterile raw materials double cone mixed, triple outlet and other high-risk areas of clean protection.
1. 100 layer laminar flow hood product introduction
Clean laminar flow (downflow) is a vertical one-way flow, to provide local class A environment, clean and sterile purification equipment; it is widely used in the pharmaceutical industry, in the clean environment C Create Class A, or create Class A in Class B clean environment. Has been very widely used in the pharmaceutical factory clean room cleanliness requires a higher local area. Such as dry and hot heat sterilization cabinet outlet laminar flow protection, freeze-drying machine export laminar flow protection, sterile raw materials double cone mixed, triple outlet and other high-risk areas of clean protection.

Two hundred laminar flow hoods
Clean laminar flow hood (laminar flow hood, down flow) by sus304 chassis, high efficiency filter, variable air volume fan, wind speed and differential pressure detector, lighting components and other major components. Chassis with no fingerprints stainless steel SUS304 production, sheet metal one bending production, beautiful and clean, easy to clean and disinfect.
Clean laminar flow hood (laminar flow, down flow) with lifting and bracket installation. There are two kinds of ways: air supply, air supply, and air supply. Use the situation to give a reasonable design.

3. 100-layer laminar flow hood parameter configuration
1, fan: domestic & import
2, the filter: tank seal & plate seal
3, plate: 1.2 resistant fingerprint board
4, the wind surface uniform way: the flow plate and the flow film
5, the control mode: (PLC + touch screen + wind speed sensor + differential pressure sensor) & (button + stepless governor + wind speed display + differential pressure table).
6, installation: ceiling installation & bracket installation.
7, cleanliness: A level
8, into the wind direction: the top into the wind and side into the wind
9, wind speed: 0.36-0.54m / s
10, noise: 56 dB or less